Skip to content
masarrayPublic

About

ArSee is a free IEC 60870 protocol tester that explains what the device is really saying. It turns IEC 101/103/104 raw TX/RX traffic into readable frame interpretation, event logs, Smart Findings, and PDF evidence reports for FAT, SAT, commissioning, troubleshooting, homologation, certification attachments, and handover.

Topics

Resources

Code of conduct

Contributing

Security policy

Stars

15 stars

Watchers

0 watching

Forks

Latest commit

 

History

542 Commits

Folders and files

ArSee · IEC 60870 Protocol Tester & Analyzer

Understand the exchange. Find the issue. Keep the evidence.

ArSee is a free, open-source Windows engineering tool for IEC 60870-5-101, IEC 60870-5-103 and IEC 60870-5-104. Inspect original TX/RX frames alongside decoded values, events, diagnostics and evidence-linked findings, then prepare a native PDF report for engineering review.

CI Website Apache 2.0 Windows x64

Product website · Download · Watch the demo · Quick Start · Field Wiki

See ArSee in action

Animated demonstration of the ArSee IEC 60870 software interface

Open the original animated GIF · Watch the website demo

Download for Windows x64

Latest public stable: v3.6.20 · Free to use · No subscription or activation key.

Package Official download
Installer — per-user Windows setup ArSee v3.6.20 Setup EXE
Portable — extract and run ArSee v3.6.20 ZIP
Integrity & release notes SHA-256 checksums · Versioned release

Official release packages may be unsigned. Use the download guide for setup, portable use and upgrade guidance.

Interface screenshots

See the actual Windows application directly in this README. Click a screenshot for its original resolution.

Signal monitoring Event investigation
ArSee Values Viewer — decoded IEC signal values and quality ArSee Event Journal — received event history
Values Viewer — live decoded point values Event Journal — observations and timestamps
ArSee Frame Trace — original TX RX frames and interpretation ArSee protocol communication diagnostics
Frame Trace — original TX/RX evidence Diagnostics — link and protocol behavior
ArSee Signal List editor — mapping and engineering scaling ArSee Smart Findings and operator evidence
Signal Map — engineer-owned point mapping Smart Findings — evidence-led explanations
ArSee report workspace with PDF preview and export ArSee sample native PDF evidence report
Report Workspace — preview before export PDF Evidence — document the session
ArSee IEC 60870-5-101 serial setup ArSee IEC 60870-5-103 serial relay setup
IEC-101 Setup — RTU serial parameters IEC-103 Setup — protection relay parameters

ArSee IEC 60870-5-104 TCP/IP setup

IEC-104 Setup — TCP/IP communication profile

From a connection symptom to engineering evidence

When a serial or TCP session looks connected but SCADA values are missing, the next question is what actually happened on the wire? ArSee connects the original protocol frames with their interpretation so engineers can move from symptoms to supporting observations.

Workflow What you can inspect
Connect and observe IEC-101 active unbalanced single/A-B serial, IEC-103 serial and IEC-104 TCP, plus separate receive-only IEC-101 monitoring
Inspect the exchange Original TX/RX telegrams, selected-frame interpretation, protocol fields, addresses, errors and diagnostics
Understand the signals Value snapshots, events, project-specific signal mapping and engineering-unit scaling
Investigate issues Smart Findings, GI and command-feedback evidence where supported, with source-frame references
Document the work Evidence report preview and native PDF export

The original communication remains inspectable even when decoding is incomplete or a signal has no project mapping.

Practical workflow

  1. Configure IEC-101/103 serial or IEC-104 TCP using authorized project parameters; passive and offline workflows are available where appropriate.
  2. Connect or capture and observe what ArSee received or transmitted in Frame Trace.
  3. Investigate the relevant Values, Events, GI/Controls and Smart Findings; follow references back to original evidence.
  4. Document the session with the built-in PDF report.

Explore screenshots and the demo · Step-by-step Quick Start · Full User Guide

Detailed feature reference

ArSee is designed around a practical path: Configure → Connect / Capture → Observe → Investigate → Report. The tables below describe supported engineering workflows; the exact protocol mode and published build determine which controls are available.

IEC 60870-5-101 · Serial RTU and gateway testing

Feature Engineering use
Active unbalanced master Configure COM port, baud rate, framing, link address, ASDU field lengths and device-specific startup settings.
Link-layer interpretation Observe FT1.2 telegram structure, link functions, ACD/DFC, acknowledged responses and Class 1/Class 2 polling.
General Interrogation (GI) Observe the request, confirmations, returned data and termination as separate protocol milestones. The configured on-connect GI policy is respected.
Commands and feedback Inspect supported reads, time synchronization and direct/select-before-operate command transactions in authorized test sessions.
Dual-link A/B Observe independent link health, active/standby ownership, switchover reasons and Redundancy timeline details.
Passive RX-only monitor Receive-only serial observation, including supported multi-RX monitoring workflows; electrical isolation depends on hardware.
Serial recovery diagnostics Distinguish link status, incomplete frames and reconnect behavior without fabricating values or command outcomes.

IEC 60870-5-103 · Protection relay testing

  • Serial master communication with configurable port, serial profile and link address.
  • Link exchange and reset visibility, supported relay Class 1/Class 2 polling and event diagnostics.
  • Supported FUN/INF interpretation, relay indications, measured values and event timestamps where provided.
  • Project-specific mapping for relay signal identities; unknown vendor information stays explicitly unclassified.

IEC 60870-5-104 · TCP/IP testing

  • TCP client/master connection to project-approved IEC-104 endpoints.
  • I-format, S-format and U-format frame interpretation with sequence and session context.
  • STARTDT / STOPDT / TESTFR control exchange and supported ASDU data inspection.
  • General Interrogation, spontaneous event/value analysis and supported command-feedback evidence.
  • Source-aware diagnostics for session continuity and transaction behavior.

Frame Trace, protocol decoder and diagnostics

  • Original TX/RX evidence: inspect observed telegrams alongside selected-frame interpretation; undecodable or malformed bytes remain visible as raw evidence.
  • Detailed protocol fields: Type ID, Cause of Transmission, Common Address, IOA, flags, quality and timestamps; IEC-103 FUN/INF and IEC-104 APCI where applicable.
  • Operator investigation: search, inspect, navigate history and use supported AUTO/HOLD viewport controls without conflating display following with traffic capture.
  • Communication diagnostics: investigate missing data even when a serial link or TCP socket appears connected; inspect GI/command phase observations and protocol irregularities.
  • Evidence links: where available, move from event/finding context to an original source frame rather than using a guessed interpretation.

Values, Event Journal and Signal Map

Workspace What it provides
Values Viewer Current decoded point states, analog measurements, counts and available quality flags.
Event Journal / SOE Time-ordered decoded observations, digital/analog filters, search and source timestamps when supplied; missing device time is not invented.
Signal List User-defined CA/IOA/Type ID identities, Bay/TYPE/Mnemonic names and state mappings; applicable IEC-103 FUN/INF mapping.
Engineering scaling Factor and two-point X0/X100/Y0/Y100 conversion for applicable normalized/scaled measurements without altering the original telegram.
Mapping editor Search/filter, selection and spreadsheet-style editing, validated paste, Fill Down and Undo/Redo where supported.
Profile preservation Existing user mappings remain user-owned. Reference profile ranges are examples, not universal RTU engineering units.

General Interrogation, Controls and Redundancy

  • GI status: differentiate original request, ACTCON, GI data and ACTTERM. Completion of one phase is not proof that every configured signal arrived.
  • Command Panel: supported Read IOA, clock sync, control qualifier and select/execute workflows with response and timeout evidence, where available in the selected mode.
  • Feedback truth: distinguish a protocol confirmation, negative confirmation, missing feedback and actual physical operation; ArSee does not assume a breaker moved.
  • IEC-101 A/B: inspect active/standby state, selected Reason/Result timeline and link-specific evidence without treating the two COM connections as one source.

Smart Findings and Operator Evidence

  • Contextual findings for supported issues such as Common Address mismatch, GI gaps, missing ACTCON/ACTTERM, command timeout and IEC-104 session instability.
  • Findings emphasize problem, protocol proof, possible cause and next action, not unexplained scores.
  • Events, trace and findings preserve source references where available; a missing original TX frame is shown as incomplete evidence rather than manufactured.
  • Separates observed facts from inferred explanations and uncertain or unsupported protocol content.

Captures, exports and native reporting

  • Save and reopen supported capture evidence for offline investigation; archived completeness is distinct from an on-screen bounded trace.
  • Supported Trace TXT, Events CSV and capture workflows alongside source-aware report content.
  • Integrated native PDF preview/export with communications evidence, event details and findings where present.
  • Review or redact confidential station names, IP addresses, signal details and customer identifiers before sharing.

User experience, learning and distribution

  • Compact Windows engineering desktop with Setup, Trace, Values, Events, Diagnostics, Signal Mapping, Controls, GI, Redundancy and Report workspaces as applicable.
  • Bilingual English and Indonesian Help Center / Field Wiki, step-by-step guidance, trace-lab examples and troubleshooting documentation.
  • Windows x64 installer and portable ZIP, with stable-channel update behavior for installed editions and explicit manual updates for portable ZIP.
  • Published Apache-2.0 source, CI, SHA-256 checksums, SBOM and build provenance for release traceability.

For configuration details, see the User Guide, Quick Start, Protocol Coverage and Field Wiki. Screenshots are interface illustrations, not claims of universal interoperability.

Open source and traceable releases

ArSee is published under Apache-2.0 with a public source tree, contribution and security policies, automated CI and versioned Windows releases. Release packages include published SHA-256 hashes and software supply-chain metadata.

Source code · CI · Windows package workflow · Security · Changelog

These controls support transparency and traceability of the software build. They do not imply accredited IEC conformance or universal physical RTU interoperability.

Compatibility and scope

Upgrading legacy installations: The Windows executable is ArSee.exe. New installers and release assets use ArSee, while legacy user data paths remain compatible. For v3.6.17/v3.6.18 installed under Programs/ARIEC60870, close active IEC/capture sessions and run the official v3.6.20 installer directly. Preserve %LOCALAPPDATA%/ARIEC60870 user data and mappings. Migration guidance.

ArSee is an engineering tester/analyzer, not a production SCADA master or an accredited conformance test suite. Use active operations only on authorized systems. A protocol acknowledgment does not by itself prove physical control operation. IEC-101 balanced mode and universal multi-vendor compatibility are not advertised.

Learn and contribute

Field Wiki · Quick Start · Troubleshooting · Architecture · Roadmap · Release history

Contributing · Issues · Support · Code of Conduct · License · Third-party notices

Remove sensitive customer identifiers, credentials, topology and private captures before submitting public reports.

About

ArSee is a free IEC 60870 protocol tester that explains what the device is really saying. It turns IEC 101/103/104 raw TX/RX traffic into readable frame interpretation, event logs, Smart Findings, and PDF evidence reports for FAT, SAT, commissioning, troubleshooting, homologation, certification attachments, and handover.

Topics

Resources

Code of conduct

Contributing

Security policy

Stars

15 stars

Watchers

0 watching

Forks

Releases

Packages

Used by

Contributors

Languages