Summary

Urgent main CI hotfix: restores packages / flow core lint (ruff, mypy) across all PRs.

Root Cause

When #2300 split run_loop(...) into run_loop(...) + _run_loop(...) for _stop_signals_interrupt(), run_loop(...) accepted stop_requested: Optional[threading.Event] = None (passed by windows_service.py:285), but did not forward stop_requested into _run_loop(...) or declare it on _run_loop's signature. As a result, line 455 (retry_stop = stop_requested if stop_requested is not None else stop) triggered two Ruff F821 undefined-name errors and would raise NameError at runtime when once=False.

Fix

  • Forward stop_requested=stop_requested from run_loop() to _run_loop() and add stop_requested: Optional[threading.Event] = None to _run_loop() in packages/flow/openadapt_flow/connector/daemon.py (+2 lines).

Verification

  • ruff check openadapt_flow/connector — passed
  • ruff format --check openadapt_flow/connector/daemon.py — passed
  • mypy openadapt_flow/connector/daemon.py — 0 issues
  • pytest -q tests/test_connector*.py — 211 passed, 81 subtests passed

Generality & Durability

  1. No per-app code in the engine: Yes — connector daemon lifecycle wiring only.
  2. Fix the class, not the instance: Yes — completes the run_loop -> _run_loop parameter forwarding so every caller (including windows_service.py) gets cooperative stop signaling.
  3. Held-out evidence: Not applicable — parameter-forwarding bug fix verified by the full 211-test connector suite.

@abrichr

abrichr commented Nov 22, 2026

Copy link
Copy Markdown
Member Author

Independent adversarial review: APPROVE

From: Grok
Reviewed-Head: 29ee8ac

Review only. I am not merging this hotfix.

The unique diff vs current main (c71d463de7821b898eb5367803ce5b45947ec7c6) is the two lines claimed: run_loop now forwards stop_requested=stop_requested into _run_loop, and _run_loop declares stop_requested: Optional[threading.Event] = None. That is the name _run_loop already reads at retry_stop = stop_requested if stop_requested is not None else stop (now line 457). On main that read is an F821 / runtime NameError whenever once=False.

This matches the Windows service caller, which already passes stop_requested=stop_event into run_loop. When that event is set, the poll loop exits, and the existing finally: stop.set() still stops the heartbeat thread and drains jobs. Callers that omit the argument keep the previous behavior (retry_stop is the local stop event). No app-specific engine change.

This is the straightforward fix for the #2300 split. I did not find a remaining unbound use of stop_requested.

Nit, not blocking this hotfix: there is still no regression test that run_loop(..., once=False, stop_requested=event) actually forwards the event and exits without a NameError. The existing connector tests did not catch the #2300 miss. Worth adding in a follow-up.

I approve this head. I am not merging it.